Installation of aerogel blanket on steam pipelines of Xinjiang Keramay oil field

Number of visits: Date:2017-11-14

Customer Profile

CompanyCNPC Keramay Branch

Projection locationKeramay Viscous Oil Production Plant

Equipment/pipelineAbove-ground steam pipeline

Operation Conditions

Pipeline diameter114mm

Interior liquid temperature320

Wind speed0.1m/s

Pipeline length5000m

Challenges

1, Considerations of economy and of energy conservation are two important factors, therefore, a solution of aerogel blanket mixed with other insulation materials is recommended.

2, Thermal bridges associated with pipe racks must be stopped in order to further minimized heat loss.

3, Water-proof performance must be improved. 

Products

Aerogel blanket DRT061010mm thickness

Aerogel blanket DRT06066mm thickness

Solution

A mixed solution of aerogel blanket and other insulation material, from interior to exterior:2 layers of 6mm thickness aerogel blanket + 70mm silicate compound + 20mm rubber foam + aluminum cladding

Noted: Glass fiber fabric with single-face aluminum foil was applied in between every 2 layers of aerogel blanket to prevent heat leakage from the gaps.

Data Comparison

Insulation Solution

 

Silicate compound

Mixed solution of aerogel blanket and other insulation materials

Pipeline diameter

mm

114

114

Interior liquid temperature

320

320

Ambient temperature

4

4

Wind speed

m/s

0.1

0.1

Thermal conductivity of insulation material

W/(m*℃

0.049complete insulation structure

0.037complete insulation structure

Thickness for insulation

mm

137.7

102

Heat dissipation area

m2

1.223

0.99852

Surface temperature of insulation

16

13

Heat loss after insulation

W/m

85.9

69.17

Heat loss of pipe supports after insulation

W/two

251.8

65.1

Plus and minus

 

Cracks and heat leakage from gaps happen

Even insulation structure, no heat leakage from gaps

 

Benefits

After replacement, heat loss of pipe supports after insulation was decreased by 74.1%, heat loss of pipeline after insulation was decreased by 19.5%, overall heat loss was decreased by 33.3%.

Pictures from Project Site

 

TypeInfo: Case Studies

Keywords for the information:

weixinLet’s, together, contribute our best share to make this planet a better place for our later generations. Call now : 86-020-83860079/020-83742867 Or contact by the following means.